Cameron choke manifold systems manage well pressure fluctuations encountered during drilling by diverting flow through a series of valves and chokes. Cameron was the first to provide 20,000- and 25,000-psi choke and kill manifolds for high-pressure drilling operations. Service applications range from noncorrosive to extreme sour oil and gas.
Our manual and hydraulic drilling chokes allow maximum operational flexibility and control in working pressures from 5,000 to 20,000 psi, as well as field-replaceable components that simplify maintenance. All manifolds can be controlled remotely or via a local control panel.
Specifications Pressures5,000 psi to 25,000 psi
Material class
DD-0.5 to EE-NL
L to X (–50 to 350 degF [–45 to 176 degC])
Standard or custom configurations, instrumentation for pressure readings, ports for glycol injections, various structural components to operate chokes and valves, etc.